BPQTF - STAY-SILV 45
- MSDS: BPQTF
- Manufacturer: HARRIS J W CO INC
- Product Name: STAY-SILV 45
- National Stock Number: 3439-00-348-9419
Product Identification
Product ID:STAY-SILV 45
MSDS Date:11/01/1985
FSC:3439
NIIN:00-348-9419
MSDS Number: BPQTF
Responsible Party
CINCINNATI, OH 45242-4110
US
Emergency Phone: 800-424-9300
Info Phone: 513-891-2000
Cage: JO820
Contractor
Telephone: 513-891-2000
Cage: 27911
Ingredients
SILVER (SARA III)
CAS: 7440-22-4
RTECS: VW3500000
Fraction By Weight: 45%
OSHA PEL 0.01 MG/M3
ACGIH TLV: 0.1 MG/M3; 9293
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
COPPER (SARA III)
CAS: 7440-50-8
RTECS: GL5325000
Fraction By Weight: 15.5%
OSHA PEL 0.1MG/M3 FUME/1 DUST
ACGIH TLV: 0.2MG/M3 FUME; 9293
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
ZINC (SARA III)
CAS: 7440-66-6
RTECS: ZG8600000
Fraction By Weight: 16-20%
OSHA PEL 10 MG ZNO/M3
ACGIH TLV: 10 MG ZNO/M3; 9293
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
CADMIUM (SARA III)
CAS: 7440-43-9
RTECS: EU9800000
Fraction By Weight: 24%
OSHA PEL SEE 1910.1027
ACGIH TLV: 0.01 MG/M3 DUST;9394
EPA Report Quantity: 10 LBS
DOT Report Quantity: 10 LBS
Hazards
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ACUTE: INHALATION OF GASES AND VAPORS
PRODUCED DURING BRAZING OPERATIONS MAY CAUSE "METAL FUME
FEVER"AND/OR IRRITATION OF UPPER RESPIRATORY TRACT. SEVERE
OVEREXPOSURE MAY CAUSE PULMONARY EDEMA WHICH C AN BE FATAL.
CHRONIC: PROLONGED OR REPEATED INHALATION OF FUMES MAY CAUSE
RESPIRATORY IRRITATION, LUNG OR KIDNEY DAMAGE.
Explanation of Carcinogenicity:CADMIUM IS LISTED AS A PROBABLE OR
POSSIBLE CARCINOGEN BY IARC AND NTP.
Effects of Overexposure:COUGHING, SHORTNESS OF BREATH, NAUSEA, FEVER,
BODYACHE, CHILLS, SNEEZING, CHEST PAIN.
Medical Cond Aggravated by Exposure:INDIVIDUALS WITH IMPAIRED PULMONARY
FUNCTIONS OR ILLNESS MAY HAVE SYMPTOMS EXACERBATED BY FUME
IRRITANTS.
First Aid
First Aid:REMOVE FROM DUST OR FUME EXPOSURE. IF BREATHING IS STOPPED
GIVE ARTIFICIAL RESPIRATION. IF BREATHING DIFFICULT, GIVE OXYGEN.
GET IMMEDIATE MEDICAL ATTENTION.
Fire Fighting
Flash Point:NONE
Extinguishing Media:MEDIA APPROPRIATE FOR SURROUNDING FIRE.
Fire Fighting Procedures:WEAR SELF-CONTAINED BREATHING APPARATUS AND
BUNKER GEAR.
Unusual Fire/Explosion Hazard:NONE SPECIFIED BY MANUFACTURER.
Accidental Release
Spill Release Procedures:NONE SPECIFIED BY MANUFACTURER. SWEEP UP OR
PLACE SPILLED MATERIAL/WASTE IN A CONTAINER FOR LATER DISPOSAL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:NONE SPECIFIED BY MANUFACTURER.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.
Exposure Controls
Respiratory Protection:USE NIOSH/MSHA APPROVED RESPIRATOR OR AIR
SUPPLIED RESPIRATOR WHEN BRAZING IN CONFINED SPACE OR WHERE LOCAL
EXHAUST OR MECHANICAL VENTILATION DOES NOT KEEP EXPOSURE BELOW TLV.
USE IN ACCORDANCE WITH 2 9 CFR 1910.134.
Ventilation:USE ADEQUATE LOCAL EXHAUST/MECHANICAL VENTILATION TO
MAINTAIN EXPOSUE BELOW TLV.
Protective Gloves:WORK GLOVES
Eye Protection:SAFETY GLASSES, GOGGLES, FACE SHIELD
Other Protective Equipment:PROPER LENSES FOR FACESHIELD
Work Hygienic Practices:WASH HANDS AFTER USE AND BEFORE EATING,
DRINKING, OR SMOKING.
Supplemental Safety and Health
Chemical Properties
HCC:N1
Appearance and Odor:SOLID WIRE OR ROD. ROD MAY BE COATED WITH A
CHEMICAL FLUX. FLUX MAY BE COLORED.
Stability
Stability Indicator/Materials to Avoid:YES
NONE SPECIFIED BY MANUFACTURER.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:COMPLEX MIXTURE OF GASES AND FUMES.
Disposal
Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH LOCAL, STATE AND
FEDERAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.